DTX-1800 Specifications
 

Free Ground Shipping!
On Orders Over $99.00

 

 

 

in the 48 Contiguous States

   
   HOME | CONTACT US
Buttsets
Cable Assemblies
Cable Certifiers
Cable Testers
Coaxial Products
Connectivity
Crimp Tools
Cutters / Scissors
Fiber Optic Supplies
Fiber Optic Cleaning
Fiber Optic OTDR's
Fiber Optic Testing
Fiber Tools
Fiber Tool Kits
Fiber Media Converters
Fishing & Pulling
Fusion Splicers
Hand Tools
Hole Making
Holster Tool kits
Multifunction Tools
Multimeters
Power Tools
Printers - Brady
Punchdown Tools
Racks and Shelves
Test Adapters
Tone & probe Kits
Tool Bags & Cases
Tool Kits
Wire Managers
Wire Strippers
Wire Wrap Guns
 
Manufacturers Index
   

 

 

 

 

Order By Phone 1-800-543-4333
 

In stock products will ship the same day if your order is placed by 4pm EST Mon-Fri.
 

DTX-1800 Specifications
 

Cable Types Shielded and unshielded Twisted Pair (STP, FTP, SSTP and UTP) LAN cabling:
Standard Link Interface Adapters  
  • TIA Category 3, 4, 5, 5E and 6: 100Ω
  • ISO/IEC Class C and D: 100Ω and 120Ω
  • ISO/ IEC Class E, 100W ISO/ IEC Class F, 100Ω
  • Cat 6/ Class E permanent link adapters Plug type and life: shielded and unshielded cable, TIA Cat 3, 4, 5, 5e, and 6 and ISO/IEC Class C, D and E permanent link
  • Cat 6/Class E channel adapters Plug type and life: shielded and unshielded cable, TIA Cat 3, 4, 5, 5e, and 6 and ISO/IEC Class C, D and E channels
Test Standards
  • TIA Category 3 and 5e per TIA/EIA-568B
  • TIA Category 5 (1000BASE-T) per TIA TSB-95
  • TIA Category 6 per TIA/EIA-568B.2-1
  • TIA Category 6A per TIA/EIA-568B.2-10 (DTX-1800 only)
  • TIA TSB-155 (DTX-1800 only)
  • ISO/IEC 11801 Class C, D, and E
  • ISO/IEC 11801 Class Ea, F (DTX-1800 only)
  • EN 50173 Class C, D, E
  • EN 50173 Class F (DTX-1800 only)
  • ANSI TP-PMD
  • IEEE 802.3 10BASE-T, 100BASE-TX, 1000BASE-T
  • IEEE 802.3an 10GBASE-T
  • IEEE 802.5 (STP cabling, IBM Type 1, 150Ω ) Token Ring, 4 Mbps and 16 Mbps
Speed of Autotest Full 2-way Autotest of Category 6 Twisted-Pair links in 9 seconds or less
Full 2-way Autotest of ISO/IEC Class F links in 22 seconds
Supported Tests Parameters (The selected test standard determines the test parameters and the frequency range of the tests)

Wire Map
Length
Propagation Delay
Delay Skew
DC Loop Resistance
Insertion Loss (Attenuation)
Return Loss (RL), RL @ Remote
NEXT, NEXT @ Remote
Attenuation-to-crosstalk Ratio (ACR), ACR @ Remote
ELFEXT, ELFEXT @ Remote
Power Sum ELFEXT, PSELFEXT @ Remote
Power Sum NEXT, PSNEXT @ Remote
Power Sum ACR, PSACR @ Remote
 

Cable Tone Generator Generates tones that can be detected by a tone probe such as a Fluke Networks IntelliTone probe. The tones are generated on all pairs. Frequency range on all pairs. Frequency range of tones: 440 Hz to 831 Hz
Display 3.7 in (9.4 cm) diagonal, 240 dots wide by 320 dots high, passive color, transmissive LCD with backlight.
Input Protection Protected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage.
Case High impact plastic with shock absorbing overmold
Dimensions Main unit and Smart Remote: 8.5 in x 4.4 in x 2.4 in (21.6 cm x 11.2 cm x 6cm), nominal
Weight 2.4 lb (1.1 kg), nominal (without adapter or module)
Operating Temperature 32°F to 104°F (0°C to 40°C)
Storage Temperature -4°F to 힍°F (-20°C to °C)
Operating relative humidity (% RH without condensation) 32°F to 95 °F (0°C to 35°C): 0 % to 90 % 95°F to 113°F (35°C to 45°C): 0 % to 70 %
Vibration Random, 2 g, 5 Hz -500 Hz
Shock 1 m drop test with and without module and adapter attached
Safety CSA C22.2 No. 1010.1: 1992 EN 61010-1 1st Edition Amendments 1, 2
Pollution degree Pollution Degree 2 as defined in IEC 60664 and applied to IEC 60950 "Safety of Information Technology Equipment, 1999"
Altitude Operating: 4000 m; Storage: 12000 m
EMC EN 61326-1
Power Main unit and remote: Lithium-ion battery pack, 7.4 V, 4000 mAh
  • Typical battery life: 12 to 14 hours
  • Charge time (with tester off): 4 hours (below 40 °C)
  • AC adapter/charger, USA version: Linear power supply; Input 108 V ac to 132 V ac, 60 Hz ; Output 15 V dc, 1.2 A
  • AC adapter/charger, international version: Switching power supply; Input 90 V ac to 264 V ac, 48 to 62 Hz; Output 15 V dc, 1.2 A (isolated output)
  • Memory backup power in main unit: Lithium battery
  • Typical life of lithium battery: 5 years
  • The battery will not charge at temperatures outside of 0°C to 45°C (32°F to 113°F). The battery charges at a reduced rate between 40°C and 45°C (104°F and 113°F).
Languages Supported English, French, German, Spanish, Portuguese, Italian, Japanese, and Simplified Chinese
Calibration Service center calibration period is 1 year
Performance Specifications Note: all specifications for tests on twisted-pair cabling apply to 100 Ω   cable. Contact Fluke Networks for information on measurement performance for cable with a different impedance.
Baseline accuracy The baseline accuracy of all DTX Series testers meets or exceeds the requirements of Level IV as in draft 2nd Edition of IEC 61935-1 over the frequency range supported by the tester.
Category 6/Class E link test modes (and lower link categories) DTX CableAnalyzer far exceeds Level III requirements of TIA/EIA-568-B.2-2 and IEC 61935-1
Class F link test modes DTX-1800 is compliant with Level IV requirements as in the draft 2nd edition of IEC 61935-1.
Length for Twisted Pair Cabling (Length specs do not include the uncertainty of the cable's NVP Value)
Parameter Single-ended Test
Dual-ended Test (Main and Remote)
Range 800 m (2600 ft) - Single-ended Test
150 m (490 ft) - Dual-ended Test (Main and Remote)
Resolution 0.1 m or 1 ft - Single-ended Test
0.1 m or 1 ft - Dual-ended Test (Main and Remote)
Accuracy ± (1m 4%) - Single-ended Test
± (1m 4%) - Dual-ended Test (Main and Remote)
Delay Skew
Parameter Twisted Pair Cabling
Range 0 ns to 100 ns
Resolution 1 ns
Accuracy ± 10 ns
DC Loop Resistance Test
Parameter Twisted Pair Cabling
Range O Ω  to 53Ω
Resolution 0.1 Ω
Accuracy ± (1 Ω 1%)
Overload Recovery Time Less than 10 minutes to rated accuracy following over-voltage. Referencing is required after repeated or prolonged over-voltage.
 
 