Butt sets
Cable certifiers
Cable testers
Coaxial products
Connectivity
Crimp tools
Cutters / scissors
Distance Meters
Electrician tool kits
Fiber optic
Fiber optic cleaning
Fiber optic testing
Fiber optic tool kits
Fishing & Pulling
Hand carts
Hand tools
Holster kits
Knives
Multifunction tools
Multimeters
Printers
Punchdown tools
Safety equipment
Soldering
Stud finders
Test adapters
Tone & probe kits
Tool bags & cases
Tool holsters
Tool kits-attaché
Tool kits-telecom
Wire managers
Wire strippers
Wire wrap guns
 
What's New!

 

 

 

Order by Phone 1-800-543-4333

In stock products will ship the same day if your order is placed by 4pm EST Mon-Fri.

Noyes Fiber Optic Test Equipment

Noyes Fiber Optic Test Equipment

View PDF

Product Overview:

Combining the CSM1-2 optical power meter and CSS1-MM Dual LED light source, the CKM-2 is a cost-effective test kit designed for performing insertion loss measurements on multimode fiber optic links.

The CSS1-MM Dual light source features 850 nm and 1300 nm LED output from a single output port and offers 2 modes of operation, continuous wave (CW) and user selectable modulated Tone. The LED output is stabilized to ensure accurate test results per current TIA/EIA requirements and equipped with a fixed SC connector. An easy to read LCD display with Backlight shows emitted wavelengths [nm], tone frequency [Hz], and ow battery condition.

The CSM1-2 optical power meter operates at 850/ 1300/ 1310/ 1550 nm and features multiple test Tone detection for fiber identification. The CSM1-2 stores optical references for each calibrated wavelength. An easy to read LCD display with Backlight shows measured power [dBm or µW] or insertion loss [dB], calibrated wavelengths, tone frequency [Hz], and Low battery condition. The CSM1 optical input port accepts Noyes thread-on style adapter caps. One adapter cap, 2.5 mm Universal, is included. A variety of Noyes thread-on style adapter caps (FC, SC, LC, etc.) may be ordered separately.

Weighing only 0.4 lb each, both units are compact and convenient for field use.The CSS1-MM Dual LED light source, and CSM1-2 optical power meter are fully N.I.S.T. traceable.

 
  Product Features

 


- Palm-sized, Rugged, Lightweight
- Certify Multimode Fiber Links per TIA/EIA Standards
- CW and Modulated Tone
- 270, 330, 1000, and 2000 Hz Supported Tone
- Power Measurements in dBm or μW; Insertion Loss in dB
- Reference Power Level Storage
- Large LCD with Backlight
- AA Alkaline, Optional NiMH or NiCd
- Automatic Power-Off Function
- Battery Gauge
- Free 50 µm and 62.5 µm Mandrels
- Cost-Effective, Easy to Use
- N.I.S.T Traceable

Noyes CKM-2 Contractor Series Multimode Test Kit with Set Reference $749.00 [Add to Cart]

Noyes Fiber Optic Test Equipment

Noyes Fiber Optic Test Equipment

View PDF

Product Overview:

Combining the CSM1-2 optical power meter, CSS1-MM Dual LED light source, and CSS1-SM Dual LASER source, the CKSM-2 is a cost-effective test kit designed for performing insertion loss measurements on multimode as well as single-mode fiber optic links.

The CSS1-MM and CSS1-SM sources feature Dual output, 850 /1300 nm LED or 1310/ 1550 nm LASER respectively, from a single output port. Both CSS1 models offer 2 modes of operation, continuous wave (CW) and user selectable modulated Tone. The CSS1-MM LED and CSS1-SM LASER output ports are stabilized to ensure accurate test results per current TIA/EIA requirements. An easy to read LCD display with Backlight shows emitted wavelengths [nm], tone frequency [Hz], and Low battery condition. The CSS1-MM model output port is equipped with a fixed SC connector while the CSS1-SM output port is equipped with Universal Connector Interface (UCI) base and SC adapter.

The CSM1-2 optical power meter operates at 850/ 1300/ 1310/ 1550 nm and features multiple test Tone detection for fiber identification. The CSM1-2 stores optical references for each calibrated wavelength. An easy to read LCD display with Backlight shows measured power [dBm or µW] or insertion loss [dB], calibrated wavelengths, tone frequency [Hz], and Low battery condition. The CSM1 optical input port accepts Noyes thread-on style adapter caps. One adapter cap, 2.5 mm Universal, is included. A variety of Noyes thread-on style adapter caps (FC, SC, LS, etc.) may be ordered separately.

Weighing only 0.4 lb each, units are compact and convenient for field use. The CSS1-MM Dual LED light source, CSS1-SM Dual LASER source, and CSM1-2 optical power meter are fully N.I.S.T. traceable.

  Product Features

 


- Palm-sized, Rugged, Lightweight
- Certify Multimode Fiber Links per TIA/EIA Standards
- CW and Modulated Tone
- 270, 330, 1000, and 2000 Hz Supported Tone
- Power Measurements in dBm or μW; Insertion Loss in dB
- Reference Power Level Storage
- Large LCD with Backlight
- AA Alkaline, Optional NiMH or NiCd
- Automatic Power-Off Function
- Battery Gauge
- Free 50 µm and 62.5 µm Mandrels
- Cost-Effective, Easy to Use
- N.I.S.T Traceable

Noyes CKSM-2 Contractor Series Multimode and Single-mode Test Kit with Set Reference $1,545.00 [Add to Cart]

Noyes MLP 1 Fiber Optic Loss Test Kit 

View PDF

MLP 1 - Basic Multimode Test Kit

Product Overview:

The MLP1 Test Kits are inexpensive solutions for testing multimode and single-mode systems.  By joining the OPM 1 Optical Power Meter and the OLS 1 Optical Light Source, the MLP 1 is a great kit for beginners or network owners. Two versions of the MLP 1 Test Kit are available for testing Premises networks, LAN, and Gigabit Ethernet. The Test Kit includes a light source, power meter, protective rubber boots, adapter cap, 50 and 62.5 Âµm mandrels, MLP1 user's guide, and carry case.

 
  Product Features

 


- Multimode and Single-mode Testing
- Loss Measurements at 850 nm and 1300 nm
- Certify 50 or 62.5 µm multimode fiber links for any 850 or 1300nm application, including Gigabit Ethernet (GBE)
- Includes 50 and 62.5 µm mandrels
- Field portable, battery operated
- N.I.S.T. Traceable

 
  Kits Includes

 


The MLP1-1S Test Kit includes:
 
- OPM1-2C Optical Power Meter and OLS1-1C Optical Light Source.

The MLP1-2 Test Kit Includes:
 
- Combines the OPM 1-2C Optical Power Meter and OLS1-2C Optical Light Source

MLP 1-1S Basic Multimode Test Kit $749.00 [Add To Cart]
MLP 1-2 Basic Multimode Test Kit $935.00 [Add To Cart]

Noyes MLP 4-2 Fiber Optic Loss Test Kit

Noyes Fiber Optic Test Equipment

View PDF

MLP4-2 Multimode Test Kit with Wave ID and Set Reference

Product Overview:

The MLP4-2 test kit combines the OPM4-2D optical power meter and OLS1-Dual LED light source and is ideally suited for testing multimode fiber optic networks.

The OLS1-Dual features 850 nm and 1300 nm LED output from a single output port and is easy to operate with only a power button and a wavelength select button. The LED output is stabilized to ensure accurate test results per current TIA/EIA requirements. This light source offers 3 modes of operation: Dual wavelengths sending ID, single wavelength sending ID, and CW. [Active Output], [Battery], and [External Power] indicators identify the currently enabled operating mode, battery charge status, and external power presence. The output port is equipped with a removable SC (FC & ST available) adapter to allow the output connector to be inspected and cleaned.

The OPM4-2D offers Wave ID, automatic wavelength identification and switching, when used with the OLS1-Dual. Multiple test Tone detection is provided for fiber identification. The OPM4-2D stores optical references for each calibrated wavelength. An easy to read Dual Wavelength LCD display with Backlight shows measured power [dBm or μW] or insertion loss [dB], calibrated wavelengths, tone signal [Hz], wavelength ID, and the battery charge status.

In addition to being powered by two AA alkaline, the OPM4-2D or OLS1-Dual can be powered by optional AC adapter and/or rechargeable NiMH battery pack.

The OPM4-2D optical input port accepts Noyes thread-on style adapter caps. Adapter caps are required for operation and must be ordered separately.

The OPM4-2D and OLS1-Dual are fully N.I.S.T. traceable.
 
  Product Features

 


- Rugged, Handheld, Lightweight
- Designed for Field Use
- Certify Multimode Fiber Links per TIA/EIA Standards
- Wave ID - Automatic Wavelength Identification and Switching
- Dual Wave ID, Single Wave ID, CW
- Large LCD with Backlight
- Power Measurements in dBm or μW; Insertion Loss in dB
- Reference Power Level Storage
- AA Alkaline, Optional Rechargeable NiMH Battery Pack or AC Adapter
- Low Battery Indicator
- Free 50 μm and 62.5 μm Mandrels
- Cost-Effective, Easy to Use
- N.I.S.T Traceable

MLP4-2 Multimode Test Kit with Wave ID and Set Reference $1,125.00 [Add To Cart]

Noyes MLP5-2B Fiber Optic Loss Test Kit

View PDF

MLP5-2B Multimode Test Kit Wave ID, Set Reference, and Data Storage

Product Overview:

The MLP5-2 test kit combines the OPM5-2D optical power meter and OLS1-Dual LED light source and is ideally suited for testing multimode fiber optic networks.

The OLS1-Dual features 850 nm and 1300 nm LED output from a single output port and is easy to operate with only a power button and a wavelength select button. The LED output is stabilized to ensure accurate test results per current TIA/EIA requirements. This light source offers 3 modes of operation: Dual wavelengths sending ID, single wavelength sending ID, and CW. [Active Output], [Battery], and [External Power] indicators identify the currently enabled operating mode, battery charge status, and external power presence. The output port is equipped with a removable SC (FC & ST available) adapter to allow the output connector to be inspected and cleaned.

The OPM5-2D offers Wave ID, automatic wavelength identification and switching, when used with the OLS1-Dual light source. The OPM5-2D stores optical references for each calibrated wavelength. An easy to read Dual Wavelength LCD display with Backlight shows measured power [dBm or μW] or insertion loss [dB], calibrated wavelengths, tone signal [Hz], wavelength ID, and the battery charge status. Up to 500 records per wavelength of power or insertion loss measurements may be stored in internal non-volatile memory.

Using the supplied Windows® compatible software and USB connection, test records may be transferred to a PC for storage, display, analysis, and printing.

In addition to being powered by two AA alkaline, the OPM5-2D or OLS1-Dual can be powered by optional AC adapter and/or rechargeable NiMH battery pack.

The OPM5-2D optical input port accepts Noyes thread-on style adapter caps. Adapter caps are required for operation and must be ordered separately.

The OPM5-2D and OLS1-Dual are fully N.I.S.T. traceable.
 
  Product Features

 


- Rugged, Handheld, Lightweight
- Designed for Field Use
- Certify Multimode Fiber Links per TIA/EIA Standards
- Wave ID - Automatic Wavelength Identification and Switching
- Dual Wave ID, Single Wave ID, CW
- Large LCD with Backlight
- Power Measurements in dBm or μW; Insertion Loss in dB
- Reference Power Level Storage
- Up to 500 Test Records per Wavelength Storage and Download
- USB Port for Download of Stored Records
- AA Alkaline, Optional Rechargeable NiMH Battery Pack or AC Adapter
- Low Battery Indicator
- Free Windows® Compatible Software to View, Print, and Archive Test Records
- Free 50 μm and 62.5 μm Mandrels
- Cost-Effective, Easy to Use
- N.I.S.T Traceable

MLP5-2B Multimode Test Kit Wave ID, Set Reference, and Data Storage $1,590.00 [Add To Cart]

Noyes SMLP5-5 Fiber Optic Loss Test Kits

View PDF

SMLP5-5 Single-Mode & Multimode Test Kit with Wave ID and Data Storage

Product Overview:

The SMLP5-5 test kit combines the OPM5-2D optical power meter and OLS4 integrated LED and LASER light source and is ideally suited for testing fiber optic networks with hybrid (single-mode and multimode) cables.

The OLS4 features 850 nm and 1300 nm LED output from a multimode output port and 1310 nm and 1550 nm LASER output from a single-mode output port. The LED and LASER outputs are stabilized to ensure accurate test results per current TIA/EIA requirements.

This light source offers 4 modes of operation: Dual wavelengths sending ID, single wavelength sending ID, CW, and modulated Tone. [Active Output], [Tone], [Battery], and [External Power] indicators identify the currently enabled operating mode, battery charge status, and external power presence. Both output ports are equipped with removable SC (FC or ST available) adapters to allow the output connectors to be inspected and cleaned.

The OPM5-2D offers Wave ID, automatic wavelength identification and switching, when used with the OLS4 light source. Multiple test Tone detection is provided for fiber identification. The OPM5-2D stores optical references for each calibrated wavelength. An easy to read Dual Wavelength LCD display with Backlight shows measured power [dBm or μW] or insertion loss [dB], calibrated wavelengths, tone signal [Hz], wavelength ID, and the battery charge status. Up to 500 records per wavelength of power or insertion loss measurements may be stored in internal non-volatile memory.

Using the supplied Windows® compatible software and USB connection, test records may be transferred to a PC for storage, display, analysis, and printing.

In addition to being powered by two AA alkaline, the OPM5-2D or OLS4 can be powered by optional AC adapter and/or rechargeable NiMH battery pack.

The OPM5-2D optical input port accepts Noyes thread-on style adapter caps. Adapter caps are required for operation and must be ordered separately.

The OPM5-2D and OLS4 are fully N.I.S.T. traceable.

  Product Features

 


- Rugged, Handheld, Lightweight
- Designed for Field Use
- Certify Multimode and Single-Mode links per TIA/EIA Standards
- Wave ID - Automatic Wavelength Identification and Switching
- Dual Wave ID, Single Wave ID, CW, and Modulated Tone (on single-mode output)
- 270 Hz, 330 Hz, 1 kHz, and 2 kHz Tone
- Large LCD with Backlight
- Power Measurements in dBm or μW; Insertion loss in dB
- Reference Power Level Storage
- Up to 500 Test Records per Wavelength Storage and Download
- USB Port for Download of Stored Records
- AA Alkaline, Optional Rechargeable NiMH Battery Pack or AC Adapter
- Low Battery Indicator
- Free Windows® Compatible Software to View, Print, and Archive Test Records
- Free 50 μm and 62.5 μm Mandrels
- Cost-Effective, Easy to Use
- N.I.S.T Traceable

SMLP5-5 Single-Mode & Multimode Test Kit with Wave ID and Data Storage $2,800.00 [Add To Cart]
 
 

 
 
 