Noyes
OPM 1 Optical Power Meter
|

Specifications Sheet

Adapter Caps |
Product Overview:
This portable optical power meter may be used
to measure optical power (dBm) in premises, telco, or broadband fiber
optic networks. When used with an LED or laser light source, the OPM1
can also measure the attenuation (insertion loss) of multimode or
single-mode cables.
With only two controls – ON/OFF and wavelength – the OPM1 is our
simplest to use optical power meter. Optical power in dBm and the
calibration wavelength setting are displayed on an easy-to-read LCD
display. The optical input port accepts Noyes thread-on style connector
adapter caps. Adapter caps are required and must be ordered separately.
The OPM1 is fully N.I.S.T. traceable and runs on a standard 9-volt
alkaline battery.
|
- 850, 1300, 1310, 1550 nm
|
|
- Premises (Ge) and Broadband (InGaAs)
Models
|
| - Displays Optical Power (dBm)
|
| - Our
Simplest to Use Optical Power Meter
|
|
- N.I.S.T Traceable
|
- The OPM 1-2C:
|
| Is calibrated at 850, 1300, 1310, and 1550 nm for testing
LAN, Ethernet, FDDI, Token Ring, and single-mode fiber systems such as
Telco, WAN, and CATV |
|
- The OPM 1-3C:
|
|
also operates at 850, 1300, 1310, and 1550 nm but offers
greater temperature stability needed for outside plant 1550 nm testing
as with WAN, CATV, and Telco systems. |
|
|
|
|
Noyes OPM 4 Optical Power Meter
|

Specifications Sheet

Adapter Caps |
Product Overview:
The OPM4 optical power meter may be used to
measure optical power in Premises, Telco, or Broadband fiber optic
networks. When used with an LED or Laser light source, the OPM4 also
measures insertion loss of multimode or single-mode cables.
The OPM4 offers Wave ID, automatic wavelength identification and
switching, when used with the OLS1-Dual or OLS2-Dual or OLS4 with Wave
ID feature. Multiple test Tone detection is provided for fiber
identification. The OPM4 stores optical references for each calibrated
wavelength. An easy to read Dual Wavelength LCD display with Backlight
shows measured power [dBm or μW] or insertion loss [dB], calibrated
wavelengths, tone signal [Hz], wavelength ID, and the battery charge
status.
In addition to being powered by two AA alkaline, the OPM4 can be powered
by optional rechargeable NiMH battery pack.
The OPM4 optical input port accepts Noyes thread-on style adapter caps.
Adapter caps are required for operation and must be ordered separately.
The OPM4 is fully N.I.S.T. traceable.
|
-Rugged, Handheld, Lightweight
|
|
-Multimode or Single-Mode
Applications
|
| -Premises (Ge), Telco (InGaAs), and Broadband (+26 dBm)
Models
|
| -Wave ID -
Automatic Wavelength Identification and Switching
|
|
-Passive Optical Networks (PON)
Testing
|
|
-Dual Wavelength
Testing
|
|
-270 Hz, 330 Hz, 1 kHz, and 2 kHz Tone
Detection
|
|
-Large LCD with Backlight
|
|
-Power Measurements in dBm or μW;
Insertion Loss in dB |
|
-Reference Power
Level Storage
|
|
-AA Alkaline,
Optional Rechargeable NiMH Battery Pack
|
|
-Battery Gauge
|
|
-N.I.S.T Traceable
|
|
Calibrated Wavelengths
|
OPM4- 1D |
OPM4- 2D |
OPM4- 3D |
OPM4- 4D |
| 660, 780, 850 |
850, 1300, 1310, 1550 |
850, 1300, 1310, 1550, 1625 |
850, 980, 1310, 1490, 1550, 1625 |
|
Noyes OPM 5 Optical Power Meter
|

Specifications Sheet

Adapter Caps |
Product Overview:
The OPM5 optical power meter may be used to
measure optical power in Premises, Telco, or Broadband fiber optic
networks. When used with an LED or Laser light source, the OPM 5 also
measures insertion loss of multimode or single-mode cables.
The OPM5 offers Wave ID, automatic wavelength identification and
switching, when used with the OLS1-Dual, OLS2-Dual, or OLS4 with Wave ID
feature. Multiple test Tone detection is provided for fiber
identification. The OPM5 stores optical references for each calibrated
wavelength. An easy to read Dual Wavelength LCD display with Backlight
shows measured power [dBm or μW] or insertion loss [dB], calibrated
wavelengths, tone signal [Hz], wavelength ID, and the battery charge
status. Up to 500 records per wavelength of power or insertion loss
measurements may be stored in internal non-volatile memory.
Using the supplied Windows® compatible software and USB connection, test
records may be transferred to a PC for storage, display, printing, and
analysis. In addition to being powered by two AA alkaline, the OPM5 can
be powered by optional AC adapter and/or rechargeable NiMH battery pack.
The OPM5 optical input port accepts Noyes thread-on style adapter caps.
Adapter caps are required for operation and must be ordered separately.
The OPM5 is fully N.I.S.T. traceable.
|
-Rugged, Handheld, Lightweight
|
|
-Multimode or Single-Mode
Applications
|
| -Premises (Ge), Telco (InGaAs), and Broadband (+26 dBm)
Models
|
| -Wave ID -
Automatic Wavelength Identification and Switching
|
|
-Passive Optical Networks (PON)
Testing
|
|
-Dual Wavelength
Testing
|
|
-270 Hz, 330 Hz, 1 kHz, and 2 kHz Tone
Detection
|
|
-Large LCD with Backlight |
|
-Power Measurements in dBm or μW;
Insertion Loss in dB
|
|
-Reference Power
Level Storage
|
|
-Up to 500 Test
Records per Wavelength Storage and Download
|
|
-USB Port for
Download of Stored Records
|
|
-Free Windows®
Compatible Software to View, Print, and Archive Test
Records
|
-AA Alkaline,
Optional Rechargeable NiMH Battery Pack or AC Adapter
-Battery Gauge
|
|
-N.I.S.T Traceable |
|
Calibrated Wavelengths
| OPM5-2D |
OPM5-3D |
OPM5-4D |
| 850, 1300, 1310, 1550 |
850, 1300, 1310, 1550, 1625 |
850, 980, 1310, 1490, 1550, 1625 |
|
Fiber Optic Power Meter
|

Click for larger image
|
Product Overview:
Do not confuse the small size of
the 560XL with its ability to provide powerful results. The optical power
meter is the perfect tool for installation and testing of fiber optic
cabling. The 560XL can be used to measure optical power or used in
conjunction with a LED or Laser source to perform insertion loss testing on
multimode and singlemode fiber optic cabling. The 560XL measures
optical power at 850nm, 1300nm, 1310nm and 1550nm. It can store reference
levels for faster, more efficient testing. The 560XL uses Snap On Connector
interface (SOC) to connect FC, SC and ST connectors.
|
- Easy to Use -
Three Buttons
Control all Functions |
|
- Loss Measurements in (dB)
Power Measurements in (dBm) |
|
- 0.01dB Measurement
Resolution |
|
- Multi-Wavelength
Storage - Stores and Recalls reference power levels for
faster, more efficient measurements |
|
- Snap on Connector Interface
Adapts to FC, SC and ST (connectors not
included) |
|
- Long Battery
Life - approx. 100 hours continuous operation |
|
- User Selectable
Auto Shut-off |
|
- Rugged and Splash-proof |
|
Calibration
Wavelengths: |
850nm, 1300nm, 1310nm and 1550nm |
|
Power Range: |
-3 dBm to -60 dBm |
|
Accuracy: |
± 0.25dB |
|
Linearity: |
+3dBm to -3dBm ±0.5dB |
|
|
-3dBm to -50dBm ±0.05dB |
|
|
-50dBm to -60dBm ±0.5dB |
|
Resolution: |
0.01dB |
|
Power
Requirements: |
Two AA size 1.5V batteries
(approx. 100 hours continuous operation) |
|
Connector
interface: |
FC, SC or ST |
|
Kingfisher Fiber Optic Power
Meter
|
 |
KI 3600 Series Fiber Optic Power Meter
|
|
Product Overview: The inexpensive KI 3600 handheld power meter is ideal for for both multimode
and single mode systems. It provides high accuracy and simplicity of use.
|
-
Auto Wavelength Detection with any Auto Test Source
|
|
-
Auto Test Instruments are Compatible Across the Kingfisher Range
|
|
-
Reliable & Easy to use with 1200 hr Battery Life
|
|
-
High Accuracy without Warm up or Dark Current Offset
|
|
-
Options for 600 - 1650 nm Wavelength, +30 to -70 dBm Power Level
|
|
-
3 - 7 Year Warranty and 3 Year Traceable Calibration
|
|
-
Supplied with metal free SC, ST, FC interchangeable connectors. Other types
include the MU and LC connector
|
|
-
dBm / dB / mW display, 0.01 dB decibel resolution
|
|
-
Display Hold and max/min Recording Function
|
|
-
Tone Detector
|
|
-
Ge Meter Suitable for General Verification
|
|
-
InGaAs Meter Suitable for all Single Mode Applications
|
|
-
Si Meter Suitable for up to 200 u Core Fiber (PCS)
|
Download
datasheet For More
Kingfisher Fiber Optic Test Equipment Click here
|
| Kingfisher
KI3600-InGaAs-MP Instrument,
Power Meter InGaAs, Blister Pack |
970.00 |
[Add to Cart] |
| Kingfisher
KI3600-H3B-MP Instrument,
Power Meter H3B, Blister Pack |
1,040.00 |
[Add to Cart] |
Kingfisher Fiber Optic Power
Meter
|
 |
KI 7600 Series Fiber Power Meters
|
|
Product Overview: A premium handheld optical power meter used to measure power, loss,
continuity and fault find on fibre systems.
|
-
Intuitive to Use, Rugged & Reliable
|
|
-
PC Interface for KITS™ Freeware
|
|
-
Memory Capacity of 1,900 Dual λ Results
|
|
-
Autotest Loss Display, with Autotest Light Source
|
|
-
>360 Hours Battery Life
|
|
-
Optional Built in 635 nm Visual Fault Locator
|
|
-
1 % Traceable Accuracy over 22 Calibrated CWDM / DWDM Wavelengths |
|
-
3 Year Calibration Cycle |
|
-
No Warm up or User Dark Current Offset
|
|
-
dBm, dB, mW , uW, nW Decibel / Linear Display Units
|
-
Metal Free Interchangeable FC, SC, ST Connector Adaptors.
(Other styles
available)
|
Download
datasheet For More
Kingfisher Fiber Optic Test Equipment Click here
|
| Kingfisher
KI7600A-InGaAs Instrument,
Power Meter InGaAs |
$1,565.00 |
[Add to Cart] |
T339E Enhanced Metal Case
Power Meter
|
 |
Product Overview:
The T339E
Enhanced Metal Case Power Meter is a ruggedized optical power meter designed
to withstand outdoor field environments. The new and improved Model T339E
utilizes advanced microprocessor technology to provide for easy, accurate
and stable calibration as well as error free, non volatile digital storage
of reference measurements.
This unit is a continuation of Wilcom’s widely used T339 series of
ruggedized optical power meters. The T339E unit has an easy to read four
digit LCD display for easy viewing and a InGaAs detector calibrated at four
wavelengths (850, 1300, 1310 and 1550nm). The unit is powered by three AA
Alkaline batteries, and can run on optional rechargeable NiCad batteries.
The unit provides user selectable modes allowing measurements in dBm,
microwatts, and relative power from +5dBm to –70 dBm. The unit also can
store a reference measurement for end-to-end loss measurements on multimode
fiber as well as measurements on singlemode fiber.
[More Info]